Supply of Fire Alarm Cable for Square Pharmaceuticals PLC

Home / Projects / Supply of Fire Alarm Cable for Square Pharmaceuticals PLC

Supply of Fire Alarm Cable for Square Pharmaceuticals PLC

Completed Projects

Overview

1. Project Overview

AMI Technologies Ltd. successfully executed a comprehensive fire alarm cable supply project for Square Pharmaceuticals PLC, one of Bangladesh's most prestigious and largest pharmaceutical companies. This project involved the supply of UL-listed, high-quality fire alarm cables to the corporate headquarters located at Square Center, ensuring the highest standards of fire safety and regulatory compliance for this critical pharmaceutical infrastructure.

Square Pharmaceuticals PLC, as a leading pharmaceutical manufacturer in Bangladesh and a key player in the South Asian pharmaceutical industry, required a reliable and code-compliant fire alarm cabling system to support their state-of-the-art fire detection and alarm infrastructure. The project was designed to meet stringent international standards including NFPA (National Fire Protection Association), BNBC (Bangladesh National Building Code), and UL (Underwriters Laboratories) requirements, ensuring optimal performance and safety for the facility's occupants and valuable assets.

2. Client Profile

Client Name: Square Pharmaceuticals PLC
Project Location: Square Center, Corporate Headquarters
Industry: Pharmaceutical Manufacturing & Healthcare
Facility Type: Corporate Office Building

Square Pharmaceuticals PLC is recognized as one of the most reputable pharmaceutical companies in Bangladesh, with a strong commitment to quality, innovation, and safety. Their corporate headquarters at Square Center serves as the nerve center for their extensive operations, housing critical administrative functions, research and development activities, quality control laboratories, and executive offices. The facility requires the highest level of fire safety infrastructure to protect both personnel and sensitive pharmaceutical data and materials.

3. Project Scope & Objectives

The primary objective of this project was to supply premium-grade, UL-listed fire alarm cables that would form the backbone of the fire detection and alarm system throughout the Square Center corporate headquarters. The project scope included:

Key Objectives:

  • Supply of UL-listed fire alarm cables compliant with NFPA 72 standards
  • Ensure cables meet power-limited fire alarm circuit (PLFA) requirements
  • Provide fire-resistant and flame-retardant cabling solutions
  • Deliver cables suitable for both plenum and non-plenum applications
  • Meet all local and international fire safety codes and regulations
  • Ensure long-term reliability and minimal maintenance requirements
  • Support the complete fire alarm system infrastructure

Technical Requirements:

  • UL Listed fire alarm cables (FPLR, FPLP classifications)
  • Compliance with NFPA 72: National Fire Alarm and Signaling Code
  • Meeting BNBC fire safety requirements
  • Appropriate gauge sizing for power and signal transmission
  • Low smoke and zero halogen properties where required
  • Color-coded identification for easy installation and maintenance
  • Proper shielding for electromagnetic interference protection

4. Products Supplied

AMI Technologies Ltd. supplied a comprehensive range of UL-listed fire alarm cables from reputable manufacturers including TIANJIE, Soloarti, and LLT. The cables supplied included:

Fire Alarm Cable Types:

a) FPLR (Fire Power Limited Riser) Cables:

  • Used for vertical riser applications between floors
  • Fire-resistant insulation and jacketing
  • Suitable for routing through shafts and risers
  • Prevents fire spread between building levels

b) FPLP (Fire Power Limited Plenum) Cables:

  • Designed for use in plenum spaces and air handling systems
  • Low smoke and flame spread characteristics
  • Meets stringent plenum ratings per NFPA 90A
  • Ideal for suspended ceiling and HVAC pathways

c) FPL (Fire Power Limited) Cables:

  • General-purpose fire alarm cables
  • For use in non-plenum, non-riser applications
  • Cost-effective solution for standard installations

Cable Specifications:

  • Conductor Size: 18 AWG to 12 AWG (as per application requirements)
  • Pair Configuration: 2-conductor, 4-conductor, and multi-pair options
  • Insulation Material: PVC, Plenum-rated materials
  • Jacket Color: Red (standard fire alarm identification)
  • Voltage Rating: 300V (power-limited circuits)
  • Temperature Rating: 60°C to 75°C operating temperature
  • Cable Construction: Solid or stranded copper conductors

5. Technical Standards & Compliance

All fire alarm cables supplied for this project met or exceeded the following standards and certifications:

International Standards:

  • UL 1424: Standard for Cables for Power-Limited Fire-Alarm Circuits
  • NFPA 72: National Fire Alarm and Signaling Code requirements
  • UL 2196: Standard for Tests of Fire Resistive Cables
  • NFPA 70 (NEC): National Electrical Code Article 760

Local Standards:

  • BNBC (Bangladesh National Building Code): Fire safety provisions
  • Local electrical and fire safety regulations

Performance Characteristics:

  • Flame propagation resistance per UL vertical flame test
  • Low smoke generation characteristics
  • Acid gas emission control (halogen-free options)
  • Circuit integrity during fire conditions
  • Electromagnetic compatibility and interference resistance

6. Project Implementation Approach

AMI Technologies Ltd. adopted a systematic and professional approach to ensure successful project delivery:

Phase 1: Assessment & Planning

  • Detailed site assessment and cable routing analysis
  • Consultation with Square Pharmaceuticals' facilities management team
  • Review of architectural and fire alarm system drawings
  • Determination of cable types, quantities, and specifications
  • Preparation of material procurement plan

Phase 2: Procurement & Quality Assurance

  • Sourcing of genuine UL-listed cables from approved manufacturers
  • Factory inspection and quality verification
  • Testing and certification documentation review
  • Proper packaging and labeling for easy identification
  • Logistics planning for timely delivery

Phase 3: Delivery & Documentation

  • Scheduled delivery to project site at Square Center
  • Proper storage and handling to prevent damage
  • Comprehensive documentation including:
    • UL certification documents
    • Technical data sheets and specifications
    • Installation guidelines and recommendations
    • Warranty documentation
    • Material test certificates

Phase 4: Technical Support

  • On-site technical consultation during installation phase
  • Guidance on proper cable routing and termination practices
  • Support for testing and commissioning activities
  • Training for maintenance personnel

7. Quality Assurance & Certifications

AMI Technologies Ltd. ensured that all fire alarm cables supplied were accompanied by proper certifications and quality documentation:

  • UL Listing Marks: Verified UL listing on cable jackets
  • Manufacturer Certifications: Original manufacturer quality certificates
  • Test Reports: Factory test reports for electrical and fire performance
  • Compliance Certificates: NFPA and BNBC compliance documentation
  • Warranty Documents: Comprehensive product warranty coverage
  • Traceability: Complete batch and lot number tracking

8. Key Project Benefits

The supply of high-quality fire alarm cables provided numerous benefits to Square Pharmaceuticals PLC:

Safety & Compliance:

  • Enhanced fire safety for building occupants
  • Full compliance with local and international codes
  • Reliable signal transmission during emergencies
  • Fire-resistant properties limiting fire spread

Performance & Reliability:

  • Superior electrical performance and signal integrity
  • Long service life with minimal maintenance
  • Resistance to environmental factors
  • Consistent performance under varying conditions

Operational Benefits:

  • Reduced false alarm incidents
  • Easy troubleshooting and maintenance
  • Future-proof infrastructure for system upgrades
  • Cost-effective long-term solution

Documentation & Support:

  • Complete technical documentation for facility management
  • Ongoing technical support from AMI Technologies Ltd.
  • Clear identification and labeling system
  • Comprehensive warranty coverage

9. Project Success Factors

Several factors contributed to the successful completion of this project:

  • Expertise: AMI Technologies Ltd.'s extensive experience in fire safety solutions
  • Quality Products: Supply of genuine UL-listed cables from reputable manufacturers
  • Professional Approach: Systematic planning and execution methodology
  • Client Collaboration: Close coordination with Square Pharmaceuticals' team
  • Timely Delivery: Meeting project schedules and deadlines
  • Technical Support: Comprehensive support throughout the project lifecycle
  • Documentation: Thorough documentation for compliance and maintenance

10. Conclusion

The successful supply of fire alarm cables to Square Pharmaceuticals PLC at Square Center demonstrates AMI Technologies Ltd.'s commitment to delivering world-class fire safety solutions. This project reinforced the company's position as a trusted partner for critical infrastructure projects in Bangladesh's pharmaceutical and industrial sectors. The high-quality UL-listed cables ensure that Square Pharmaceuticals' corporate headquarters maintains the highest standards of fire safety, protecting both people and assets while meeting all regulatory requirements.

AMI Technologies Ltd. remains committed to supporting Square Pharmaceuticals PLC with ongoing technical assistance and future fire safety requirements, continuing our partnership in maintaining safe and compliant facilities for one of Bangladesh's leading pharmaceutical companies.

Chat with us on WhatsApp!
Online

Hello, how can we help you?