AURA Series Fire Protection Panels
Description
<br><div style="max-height: 350px;"><p>Pacific Tech & Engineering Limited (PTEL) presents the AURA Series Fire Protection Panels, combining modern aesthetics, superior fire resistance, and energy efficiency. Ideal for industrial, commercial, and architectural projects, these panels ensure safety and sustainability. Built to EN, ISO, and NFPA standards, PTEL’s AURA Series sets a new benchmark for innovative building safety solutions in Bangladesh.</p></div><br><div style="max-height: 350px;"><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">16 CHANNEL I/O INTERFACE CARD</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">The 16 Channel I/O Interface enhances the versatility of the alarm system by providing additional input and output capabilities to the Aura Fire Alarm Control Panel. Inputs or outputs can be selected for up to 16 individual channels, and are configured in the same way as devices connected to addressable loops of the panel. The 16 Channel I/O Interface can be configured to contribute or act upon cause and effect logic.</span></p><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">MEDIA GATEWAY™ PANEL MODULE</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">The Media Gateway Panel Module provides connectivity to monitoring centers using IP (Sur-Gard), or dial-up connectivity. The Media Gateway may also be used to meet integration application requirements.</span></p><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">8 CHANNEL RELAY PANEL MODULE</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">The 8 Channel Relay Panel Module has 8 voltagefree changeover relay contacts, each of which can be individually programmed. All outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic. These boards are typically used in applications which require more than the five standard relay outputs, such as signalling to other systems or plant control.</span></p><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">NETWORK MODULE</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">The Aura Network Module provides enhanced highspeed communication for networking fire control panels. The network provided by this module can support combinations of Aura Fire Alarm Control Panels and Aura Vision units. Aura Fire Alarm Control Panels can receive events from other panels in the network. The Class X networking used in conjunction with the Network Module provides tolerance against open and short circuit trouble conditions.</span></p><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">PRINTER</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">The Aura Printer is an optional feature for printing fire system events as they occur. The printer is located on the fascia, below the Zone LEDs (if present). It is a thermal printer and never requires replacement ink. Printing is performed on heat-sensitive paper rolls. A trouble message is reported when the paper runs out. The printer includes a frontloading feature for replacing paper rolls.</span></p><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">ZONE LED MODULE</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">The Zone LED module contains 48 LEDs and is connected to the LCD Main Processor Board of the Aura Fire Alarm Control Panel. A maximum of three Zone LED modules can be connected to provide the fascia with 144 Zone LED indicators.</span></p><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">4 CHANNEL NAC PANEL MODULE FUTURE ENHANCEMENT</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">Additional NAC output capability can be added to by using 4 Channel NAC Modules. These boards have 4 supervised NAC outputs, each of which can be individually programmed. The circuits can be configured for class A or B operation. These circuits can be configured to act upon cause and effect logic.</span></p><p style="padding: 0px; margin: 0in 0in 15.6pt; background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px;">8 CHANNEL CONVENTIONAL ZONE PANEL MODULE FUTURE ENHANCEMENT</span></span><span style="padding: 0px; margin: 0px;"><br style="padding: 0px; margin: 0px;">The 8 Channel Conventional Zone Panel Module has 8 supervised detection circuits (Class B). Each circuit can support up to 20 conventional detectors and approved devices. Individual circuits may be configured for trigger resistor or short circuit activation. These circuits may be used for any of the standard input actions and can be configured to contribute to cause and effect logic. Each pair of circuits (e.g., 1 and 2, 3 and 4, etc.) can be joined to form a single Class A configuration.</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px;"><span style="padding: 0px; margin: 0px;"><span style="padding: 0px; margin: 0px; line-height: 15.6933px;">16 CHANNEL I/O INTERFACE PANEL MODULE FUTURE ENHANCEMENT</span></span><span style="padding: 0px; margin: 0px; line-height: 15.6933px;"><br style="padding: 0px; margin: 0px;">The 16 Channel I/O Interface Panel Module will provide the same functionality as the 16 Channel I/O Interface Card, with the convenience of a plug-in-module</span></p></div><br>
